    Oxford’s report makes nitrate and manganese more useful topics than an assumed hardness problem. The borough is planning expanded iron and manganese treatment; a household plan should consider that work and the actual incoming water.

    01 · Read the report, then test your tap

    Your water in Oxford.

    Source
    Borough groundwater wells plus purchased Chester Water Authority surface waterSource · 2025 CCR · published 2026 ↗
    Hardness
    The utility does not publish hardness in this report. Chester County private-well median 81.8 mg/L (4.8 gpg) is clearly labeled regional private-well context only—not this public supply.Source · 2007–mid-2025 · homeowner samples ↗
    Disinfectant
    Free chlorine at borough wells; total chlorine reflects purchased chloraminated CWA waterSource · 2025 CCR · published 2026 ↗
    PFAS
    PFOA and PFOS are not listed in the detected table. This does not establish whether they were non-detect or not sampled.Source · 2025 ↗

    Other reported items

    Nitrate 7.82 ppm (4.16–7.82), below the 10 ppm MCL.Source · 2025 ↗

    Manganese up to 0.19 ppm, above the 0.05 ppm secondary guideline; iron up to 0.15 ppm.Source · 2025 ↗

    The borough plans an iron/manganese treatment expansion.Source · Borough treatment plans · accessed 2026 ↗

    Open the utility water quality report ↗

    The federal comparison on this page is EPA’s 2024 limit of 4 ppt for PFOA and PFOS separately.

    Source · 2024 · EPA final rule ↗

    Pennsylvania’s current limits are 14 ppt for PFOA and 18 ppt for PFOS. Where we note a result within PA limits, that does not mean it is below the federal comparison.

    Source · PA rule effective 2023 ↗

    Reverse osmosis is one of the treatment methods EPA lists for PFAS. That is not a claim that Kora equipment removes PFAS or achieves a particular removal percentage.

    Source · 2024 · EPA treatment guidance ↗

    02 · From readings to real life

    What that means for your home.

    Mineral staining needs the right measurement.

    Manganese is reported above the secondary guideline. Dark staining deserves a test and correctly selected filtration, not an automatic softener.

    Explore treatment options →

    Nitrate is not a taste diagnosis.

    The verified report figure is below its MCL, but nitrate concerns require a certified laboratory and documented contaminant-specific treatment.

    Explore treatment options →

    Read the borough’s treatment plans.

    Planned utility improvements are part of the conversation. Avoid choosing home equipment as though the public treatment arrangement cannot change.

    Explore treatment options →

    03 · Not a package for every address

    Recommended setup for most Oxford homes.

    Start with manganese-related symptoms, hardness and the borough’s treatment plan. Discuss correctly matched mineral filtration or drinking-water RO where appropriate; a certified lab handles specific nitrate questions.

    On municipal water

    A single-tank softener and carbon system with RO is a starting point when the water is hard. Bigger households of 7+ people may need a dual-tank setup. Test first, and match carbon to the disinfectant.

    Source · Kora system specifications ↗

    On a private well

    Discuss a dual-tank well system for iron, odor and hardness. Add UV or a calcite neutralizer only when appropriate testing calls for it. A certified lab handles bacteria, nitrate and PFAS questions.

    Well treatment options →

    04 · County context, not your well result

    If you’re on a well near Oxford.

    A private well outside Oxford’s network may share groundwater concerns without sharing the borough result. Sample the well for bacteria and nitrate, alongside hardness, iron, manganese and pH.

    Penn State homeowner-submitted well and spring samples, 2007–2025. These sample-set medians and percentages are not a forecast for an individual home. Iron and manganese “over limit” use the source’s comparison limits; coliform-positive and corrosive results are different indicators.

    County private-well data from Penn State homeowner samples
    CountySamplesMedian hardnessIron over limitManganese over limitColiform positiveCorrosive
    ChesterSource · 2007–2025 · Penn State ↗490Source · 2007–2025 · Penn State ↗82 mg/L (4.8 gpg)Source · 2007–2025 · Penn State ↗14.6%Source · 2007–2025 · Penn State ↗14.8%Source · 2007–2025 · Penn State ↗29.3%Source · 2007–2025 · Penn State ↗83.3%Source · 2007–2025 · Penn State ↗

    Penn State’s 2025 PFAS study found about 18% of sampled private wells exceeded the new federal PFAS limits. The highest rates were in southeastern counties, including Montgomery, Chester and Bucks.

    Source · 2025 · Penn State PFAS study ↗

    Oxford water questions.

    08

    Request your free water test & quote.

    Answer a few quick questions and we'll be in touch within one business day. Free, no obligation.

    Step 1 of 5

    20%

    What type of water do you have?

    Do you rent or own your home?

    What issues are you noticing with your water? (select any)