Serving PA · NJ · DE

    Private wells

    Common well water problems in Pennsylvania (and how to fix them)

    By Wesley Nysm, Owner, Kora Water Systems

    What county samples tell us—and what they do not

    In the supplied Penn State sample set, coliform-positive results run from 29.3% in Chester to 40.2% in Berks; Montgomery is 35.6%. Corrosive-water results are 56.8% in Montgomery, 83.3% in Chester and 76.8% in Berks. The sample counts are 571 in Montgomery, 490 in Chester and 464 in Berks. These are homeowner-submitted samples, not a probability that your well has those problems.

    The supplied iron-over-limit figures are 6.6%, 14.6% and 10.9% for Montgomery, Chester and Berks; manganese figures are 4.2%, 14.8% and 13.4%. The source comparison limits and sample-selection context matter.

    What county samples tell us—and what they do not
    CountyColiform positiveCorrosiveIron over limitManganese over limit
    Montgomery35.6%56.8%6.6%4.2%
    Chester29.3%83.3%14.6%14.8%
    Berks40.2%76.8%10.9%13.4%
    Bucks31.9%67%8.6%10.9%
    Lehigh33.7%64.5%3.8%19.8%

    Bucks and Lehigh add different well priorities

    Bucks homeowner-submitted samples have median hardness of 145.9 mg/L (8.5 gpg), with 31.9% coliform-positive and 67.0% corrosive results. Lehigh samples have median hardness of 104.2 mg/L (6.1 gpg), with 33.7% coliform-positive and 64.5% corrosive results. These are self-selected sample sets, not municipal readings or predictions for a home.

    Manganese results exceed the source comparison guideline in 10.9% of Bucks samples and 19.8% of Lehigh samples; iron figures are 8.6% and 3.8%. Lehigh’s manganese share makes dark staining a useful testing question, even when hardness is less prominent than in Allentown city water.

    Orange stains: check iron first

    Orange or rust-colored stains often point to iron, but appearance cannot tell you its concentration or form. Test iron, pH and hardness before picking media.

    For suitable wells, Kora uses a separate backwashing filter with Katalox Light, catalytic carbon and air injection, followed by a softener when needed. Our standard well discussion covers iron up to 7 ppm; above that we assess a peroxide system after testing. The iron filter backwashes without salt.

    Black stains: do not overlook manganese

    Dark deposits can suggest manganese, sometimes alongside iron. A lab result and water chemistry help distinguish mineral staining from another cause.

    Oxidation and properly selected filtration can address manganese, but performance depends on the measured water and equipment settings. Test first; do not assume a softener alone is the right treatment.

    Sulfur smell: find where it starts

    A rotten-egg odor can be associated with hydrogen sulfide or sulfur-related activity. If it only happens at the hot tap, the water heater may be involved rather than the whole well supply.

    Compare hot and cold water, check the well conditions and test before recommending air injection, catalytic carbon or another oxidation approach. Adding a tank without finding the source can miss the problem.

    Blue-green stains: look at pH and plumbing

    Blue-green marks can be related to copper corrosion in acidic water. Check pH and the plumbing; a stain is a clue, not a complete diagnosis.

    A calcite acid neutralizer can raise low pH when appropriate. It can also add hardness, so the softening decision comes after the neutralization plan—not before. Test first, and ask for lab testing if copper exposure is a concern.

    Bacteria: a certified test, then a treatment plan

    Clear water can still have bacteria. A certified lab should check total coliform and E. coli; taste and a handheld meter do not establish microbiological safety.

    If the test is positive, follow the lab and public-health guidance, investigate the well’s construction and entry points, and arrange follow-up sampling. UV can be part of a suitable treatment plan, but needs adequate pretreatment and continued maintenance. Kora’s UV schedule calls for bulb and sediment-filter changes every six months.

    Nitrate and PFAS: not something you can smell

    Nitrate can enter groundwater from several sources, including fertilizer and waste systems. PFAS can also be present without a visible clue. Both require appropriate laboratory testing; our in-home checks do not test for either.

    Penn State’s 2025 PFAS study found 30 of 167 sampled private wells (about 18%) exceeded at least one relevant federal PFAS limit. That sample finding is not a prediction for your property.

    EPA lists reverse osmosis as one treatment method for PFAS, but that does not establish PFAS performance for a Kora model. Use a certified lab and independently documented treatment performance for the specific contaminant. We do not promise removal percentages.

    Private-well testing is your responsibility

    Pennsylvania has no statewide private-well testing requirement, according to Penn State Extension. That does not mean a well is safe without testing; local requirements or property transactions may be different.

    Our free visit checks hardness, iron, pH, TDS and chlorine in about 15–20 minutes. It is not a state-certified lab test. We can help you locate a certified lab for bacteria, nitrate and PFAS before deciding what the well actually needs.

    08

    Request your free water test & quote.

    Answer a few quick questions and we'll be in touch within one business day. Free, no obligation.